by george123 » Wed Mar 22, 2023 1:29 pm
If ever a bike needed an electric start my supa 5 does.
Owned the bike now for about 9months..bought as a non-runner.
Bike will rarely start on kickstart,usually have to bumpstart in 2nd
Even then will only start 50% of the time.
Have checked everything,timing 2.5mm BTDC checked with dial gauge and degree wheel,
new points ,different carb,checked throttle and choke cables,different coil,different plugs
wired coil direct to battery and points with new wiring,not thru ignition switch
When bike fails to start when check plug..appears very slightly wet
Have checked Petroil flow from tank ok,using 50 to 1 mix..mixed in separate container ,changed petroil.
Compression check on bike returns 75psi..head is torqued to 26Nm,when try to torque above this
threads start to strip on studs,squish value ok
Have checked different Mz forums..can’t find any info for compression figures.
I suspect low compression is causing problem..but what is a good compression figure on a 1975 Mz ts250/5
Any help much appreciated
Thanks
Willie2sheds